Abstract

Aims and Objectives: High-resolution computed tomography (HRCT) temporal bone is widely used for preoperative assessment in chronic otitis media (COM) squamous. Though it identifies the extent of disease, its diagnostic reliability can be challenged by the presence of inflammation and soft tissue artefacts. This study evaluates the accuracy of HRCT by correlating radiologic predictions with definitive intraoperative findings to optimize surgical planning.

Methods: A hospital-based cross-sectional study was conducted at Bir Hospital, Kathmandu, from August 2024 to August 2025. Forty-six patients with clinically diagnosed COM squamous undergoing mastoid surgery were included. Preoperative HRCT findings were compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and Cohen’s kappa were calculated.

Results: The majority of patients were aged 21–40 years (45.65%) with slight male predominance (52.17%). Mastoid sclerosis (86.95%) and scutum erosion (100%) showed complete radiologic–surgical concordance. Facial canal erosion (21.7% vs 13.0%; p < 0.001) and stapes erosion (67.39% vs 45.65%; p = 0.015) were significantly overestimated on HRCT. HRCT demonstrated high sensitivity for ossicular erosion (malleus 90.3%, incus 95.3%, stapes 85.7%) but variable specificity. For bony erosions, sensitivity ranged from 42% (tegmen) to 83% (facial canal), with fair to moderate agreement (κ = 0.21–0.55). HRCT showed 100% sensitivity for disease extension to middle ear and mastoid subsites, with the highest agreement for mesotympanum (κ = 0.802) and sinus tympani (κ = 0.809).

Conclusion: HRCT is highly sensitive in detecting ossicular erosion and disease extent, but may exaggerate certain bony erosions. Careful radiologic–surgical correlation is essential.

Keywords: Chronic otitis media; Cholesteatoma; Computed Tomography; Ossicle

Downloads

Published

2026-11-22

How to Cite

1.
Suwal RB, Kharel B, Adhikari A, KC C, Thapa PB, KC A. Radiologic–surgical Correlation of High-resolution Computed Tomography Temporal Bone in Chronic Otitis Media Squamous. Nepalese J ENT Head Neck Surg [Internet]. 2026 Nov. 22 [cited 2026 Nov. 22];15(1):8-11. Available from: https://www.njehns.org.np/index.php/njehns/article/view/285